product description
GW pipeline high-efficiency non-clogging sewage pump is a vertical single-suction single-stage centrifugal drainage pump. Any position in the pipeline. The pump and the motor are directly connected to the same axis, which is an electromechanical integrated product, with a compact structure and stable performance. The large flow passage anti-blocking hydraulic component design is used to greatly improve the ability of dirt to pass through. It can effectively pass 5 times the fiber diameter of the pump and solid particles with a diameter of about 50% of the pump diameter. Reasonable design, reasonable supporting motor, high efficiency, and significant energy saving effect. The mechanical seal adopts hard wear-resistant tungsten carbide, which is durable and wear-resistant, which can make the pump run continuously for more than 8000 hours. Advanced hydraulic performance, high machine efficiency and low running noise. A protective cover is added to the wind blade end of the motor, and the whole machine can be placed outdoors to work without a machine room, which can save a lot of infrastructure costs. Use within the range of the lift to ensure that the motor is not overloaded.

Structure description
GW series non-blocking single-stage pipeline sewage pumps have the same inlet and outlet on the same level and have the same specifications. The vertical structure has a small footprint, the motor and the pump are coaxial, and the installation chassis is provided for easy and stable installation. The impeller uses a single ( Double) runner with good passing performance.

Application scope of pipeline type non-clogging sewage pump
GW series pipeline non-clogging sewage pump is suitable for the discharge of severely polluted wastewater from factories, sewage drainage stations in main residential areas, water distribution systems of urban sewage treatment plants, drainage systems of civil air defense systems, water supply equipment of water plants, hospitals, hotels Sewage discharge, municipal engineering construction sites, mining auxiliary equipment, rural biogas ponds, farmland irrigation, and other industries. Contaminated sewage and dirt from conveyor belts can also be used in clean water and with weakly corrosive media.

Operating conditions of pipeline type non-clogging sewage pump
A. The usage temperature of pipeline sewage pump is ≤40 ℃, humidity is ≤95%; altitude is ≤1000m.
B. The medium temperature does not exceed 60 ° C, and the medium weight is 1 ~ 1.3kg / dm3.
C, the range of use of cast iron material is PH5 ~ 9.
D, stainless steel can use general corrosive media.
E. The altitude of the use environment does not exceed 1000 meters. When the above conditions are exceeded, it should be put forward when ordering in order to provide you with more reliable products.
Note: If the user has special temperature and medium requirements, please specify the details of the conveying medium when ordering, so that the unit can provide more reliable products.

Product features of pipeline type non-clogging sewage pump
1. The pump and the motor are directly connected to the same axis, which is an electromechanical integration product, with a compact structure and stable performance.
2. The large flow channel anti-blocking hydraulic component design greatly improves the ability of dirt to pass through. It can effectively pass the fiber material 5 times the diameter of the pump and solid particles with a diameter of about 50% of the pump diameter.
3. Reasonable design, reasonable supporting motor, high efficiency, low noise, and significant energy saving effect.
4. The mechanical seal adopts hard wear-resistant tungsten carbide, which is durable and wear-resistant, which can make the pump run continuously for more than 8000 hours.
5. The pump has a vertical structure, the center line of the inlet and outlet is on the same level, and the specifications of the inlet and outlet flanges are the same. Installation and removal are very convenient.
6, small footprint, no need to build a machine room, can save a lot of infrastructure costs; add a protective cover to the motor blade end, the whole machine can be placed outdoors.

model Head specification flow nature power
(KW)
Rotating speed
(r / min)
Voltage
(V)
caliber
(mm)
flow
(m3 / h)
Head
(m)
25-8-22
25 8 twenty two 1.1 2900 380
32-10-15
32 10 15 1.5 2900
40-15-30
40 15 30 2.2 1900
50-20-7
50 20 7 0.75 1450
50-20-15
50 20 15 1.5 2900
50-15-25
50 15 25 2.2 2900
50-18-30
50 18 30 3 2900
65-25-15
65 25 15 2.2 2900
65-25-30
65 25 30 4 2900
80-40-7
80 40 7 2.2 1450
80-40-15
80 40 15 4 2900
80-65-25
80 65 25 7.5 2900
100-85-10
100 85 10 4 1450
100-100-15
100 100 15 7.5 1450
100-85-20
100 85 20 7.5 1450
100-100-25
100 100 25 11 1450
100-100-35
100 100 35 15 1450
125-115-15
125 115 15 15 1450
150-180-15
150 180 15 15 1450
150-180-20
150 180 20 18.5 1450
150-180-30
150 180 30 twenty two 1450
150-180-35
150 180 35 30 1450
200-300-10
200 300 10 11 980
200-300-15
200 300 15 twenty two 1450
200-300-20
200 300 20 30 1450
200-300-25
200 300 25 37 1450
250-600-10
250 600 10 30 980
250-600-12
250 600 12 37 1450
250-600-15
250 600 15 45 1450
250-600-20
250 600 20 55 1450
250-600-25
250 600 25 75 1450
300-800-12
300 800 12 45 980
300-480-15
300 480 15 45 1450
300-600-20
300 600 20 55 1450
300-800-20
300 800 20 20 1450

Troubleshooting centrifugal pumps

Corrosion resistance of main materials of pumps (for reference)

medium concentration
(%)
Polypropylene concentration
(%)
ABC
25 ° C 50 ° C 20 ° C 60 ° C
sulfuric acid 60 <30 X
Nitric acid 25 20 Ο
hydrochloric acid <36 <38
Hydrofluoric acid 35 40 X
acetic acid <80 <20 Ο
Sodium hydroxide 100
Potassium dichromate 25
Smelly water X Ο X
Ethanol <50
acetone 10 Ο
Tetrachloroethane Ο Ο X
Freon 22 Ο Ο
Bleach CL13% CL12.5% Ο Ο
Plating solution Ο X
Photographic fluid

medium concentration
(%)
stainless steel concentration
(%)
ceramics
25 ° C 50 ° C 25 ° C 50 ° C
sulfuric acid <5 X
Nitric acid 70
hydrochloric acid X
Hydrofluoric acid X 0 to 100 X
acetic acid <20
Sodium hydroxide 70 Ο X
Potassium dichromate 40 ~ 60 10 ~ 20
Smelly water Ο
Ethanol
acetone
Tetrachloroethane 50
Freon 22
Bleach CL12% X
Plating solution
Photographic fluid

Note: △ is excellent; √ is good; 0 is available, but there is obvious corrosion; X is severely corroded and not applicable.


Physical and mechanical properties of PVDF

performance unit according to
density g / cm3 1.75-1.79
Ratio cm3 / g 0.56-0.75
Melting range 0c 155-170
Refractive index n25D 1.42
Molding shrinkage % 2-3
Stretch strong hair (yield) Mpa 28-41
Stretching strong hair (break) Mpa 31-52
Elongation (break) % 100-400
Impact strength (no notch) KJ / m 107-214
Compressive strength Mpa 55-69
Hardness (Shore D) 70-80
Wear-resistant mg / 1000r 7.0-9.0
Limiting oxygen index (l0 I) % 44
Burning rate VD
Resistivity u194 1.0x10 15
Common dielectrics 10 31 CYCles 9.7


Polyvinylidene fluoride (PVDF) chemical resistance

Chemical media concentration
(%)
Maximum use temperature ℃ Chemical media concentration
(%)
Maximum use temperature ℃ Chemical media concentration
(%)
Maximum use temperature ℃
hydrochloric acid 36 135 Hydrogen hydroxide <10 85 Ethanol 135
sulfuric acid <60 120 Hydrogen hydroxide 50 50 Diethyl ether 50
sulfuric acid 80-93 95 Ammonium carbonate 110 formaldehyde 37 50
sulfuric acid 90 65 Calcium carbonate 135 acetone 10% water solution 50
Nitric acid <50 50 Sodium carbonate Aqueous solution 135 Hydrazine Aqueous solution 95
Phosphoric acid <85 135 Sodium bicarbonate Aqueous solution 120 benzene 75
Phosphoric acid 85 110 ammonia 110 aniline 50
acetic acid 10 110 brine 135 Toluene 85
acetic acid 80 80 Sodium hydrogen phosphate Aqueous solution 120 phenol 50
acetic acid 100 50 Calcium phosphate Aqueous solution 135 chlorobenzene 135
Trichloroacetic acid <10 95 Calcium Oxide Aqueous solution 135 Naphthalene 95
Trichloroacetic acid 50 50 Potassium oxide Aqueous solution 135 Methyl chloride 135
oxalic acid 50 Ammonium oxide Aqueous solution 135 Chloroform 50
Benzenesulfonic acid Aqueous solution 50 Iron oxide Aqueous solution 135 Carbon tetrachloride 135
Hydrofluoric acid 40-100 95 Ferrous sulfate Aqueous solution 135 Ethyl chloride 135
Hydrofluoric acid 40 120 Ammonium sulfate Aqueous solution 135 1.2 Trichloroethane 135
Hydrobromic acid 50 130 Ammonium sulfate Aqueous solution 135 1.1.2 Trichloroethane 65
Peroxyacid 10 95 Sodium nitrate Aqueous solution 135 Tetrachloroethane 120
Peroxyacid 70 50 Ammonium phosphate Aqueous solution 135 Vinyl chloride 95
Sodium hypochlorite 6-15 95 Urea Aqueous solution 120 Trichloroethylene 135
Potassium chlorate 100 carbon dioxide 80 Dichloroethylene 110
Chromic acid <40 80 carbon dioxide 75 natural gas 135
Chromic acid 50 50 carbon dioxide 65 Fuel oil 135
Potassium ferrate 120 chlorine element 95 Paraffin oil 120
hydrogen peroxide <30 95 bromine element 65
Sodium peroxide 95 iodine element 65



Corrosion performance table of fluoroplastic (for reference only)

Temperature, ℃
medium concentration% 25 200 medium concentration% Temperature, 200 ℃
sulfuric acid 0-100 Formic acid
Oleum Acetic acid 0-ice
Nitric acid 0-100 acetic acid
Oleum Propionic acid
hydrochloric acid acrylic acid
Phosphoric acid Acrylic anhydride √ (boiling point)
Hydrofluoric acid Methacrylate √ (boiling point)
Hydrobromic acid Butyric acid
Hydroiodic acid Caprylic acid
Hydrocyanic acid Lauric acid
Nitrite Palmitic acid
Nitrite Stearic acid
Chloric acid Oleic acid
Hypochlorous acid Linoleic acid
perchloric acid Abietic acid
Tetraphosphoric acid fatty acid
Carbonic acid Chloroacetic acid
Chromic acid Lactic acid
Silicic acid Oxalic acid
Boric acid Fumaric acid
Arsenic acid Citric acid
Selenic acid niacin
Fluosilicic acid
Fluoboric acid
Chlorosulfonic acid
Wang Shui
Mixed acid

medium concentration% Temperature, 200 ℃
Sodium hydroxide
Potassium hydroxide
Ammonium hydroxide
magnesium hydroxide
Calcium hydroxide
Aluminum hydroxide
Barium hydroxide
Iron hydroxide
Ferrous hydroxide
Nickel salt
Nickel sulfate
Nickel nitrate
Nickel chloride
Zinc salt
Zinc sulfate
Zinc nitrate
Zinc chloride
GW pipeline high efficiency non-clogging sewage pump product manual download
GW pipeline high efficiency non-clogging sewage pump product manual download

Tips:
Please download the "GW Pipeline High-efficiency Non-blocking Sewage Pump" product manual, unzip the file, add the micro signal "331044666" or scan the QR code below to request the decompression password.
Wechat QR code

Corporate Culture | Corporate Honor | Contact Us | Recruitment Agency | Service Support | Download Center | Jingshen Digital
Copyright ? 2019 Shanghai Shangcheng Pump & Valve Manufacturing Co., Ltd. All Rights Reserved. 沪 ICP 备 11032336 号

[Close] Free answer to Shangcheng sales engineer

Enter your mobile or landline number and click the "Free Consultation" button.
Our service staff will call you back within 15 seconds.

Please enter directly on the mobile phone: such as 13878800000
Please add the area code before the landline: eg 02168100000
We have encrypted the entire call, we have paid for your call charges, please rest assured!
The cost of free calls is paid by us, please rest assured!
Sales Hotline: 021-6810 0000
七乐彩 星力捕鱼 欢乐拼三张 欢乐拼三张